| CUT THROUGH TEST FOR ENAMELLED ROUND COPPER WINDING WIRES | ||||||||||
| (BASIS : IS 13730 - .. & IS 13778 - 6) | ||||||||||
| Nominal Conductor Diameter |
Load | Specimen Loading | Time for Insertion until Loading (s) |
Temperature C (2 min. withstand) Requirement | ||||||
| Part 3 Polyester Copper Wires Class 155 |
Part 8 Polyesterimide Copper Wires Class 180 |
Part 13 PE (PEI) + PAI Copper Wires Class 200 |
||||||||
| (mm) | (SWG) | |||||||||
| Over | Up to & Including |
From | Up to & | |||||||
| Including | (g) | (N) | ||||||||
| 0.020 | 0.032 | - | 49 | 25 | 0.25 | P | 1 | 240 | 300 | 320 |
| 0.032 | 0.050 | - | 48 | 41 | 0.40 | |||||
| 0.050 | 0.080 | 47 | 45 | 71 | 0.70 | |||||
| 0.080 | 0.125 | 44 | 40 | 128 | 1.25 | |||||
| 0.125 | 0.200 | 39 | 36 | 224 | 2.20 | |||||
| 0.200 | 0.315 | 35 | 30 | 224 | 2.20 | P | 1 | |||
| 0.315 | 0.500 | 29 | 26 | 459 | 4.50 | |||||
| 0.500 | 0.800 | 25 | 22 | 918 | 9.00 | |||||
| 0.800 | 1.000 | 21 | 20 | 1836 | 18.00 | |||||
| 1.000 | 1.250 | 19 | 18 | 1836 | 18.00 | 2 | ||||
| 1.250 | 2.000 | 17 | 15 | 3672 | 36.00 | |||||
| 2.000 | 5.000 | 14 | - | 7140 | 71.00 | 3 | ||||
| Note: In view of continuous improvements in design & process specifications given above are subject to change without notice. | ||||||||||