| PEEL TEST FOR ENAMELLED ROUND COPPER WINDING WIRES | |||||||
| (BASIS : IS 13730 - .. & IS 13778 - 3) | |||||||
| Nominal Diameter | Load (N) |
Minimum Revolutions (n) | |||||
| mm | SWG | Part 3 Polyester Copper Wires Class 155 |
Part 8 Polyesterimide Copper Wires Class 180 |
Part 13 PE (PEI) + PAI Copper Wires Class 200 |
|||
| Over | Up to & including |
From | Up to & including |
||||
| 1.00 | 1.40 | 19 | 18 | 25 | n = d (130) mm |
n = d (110) mm |
n = d (110) mm |
| 1.40 | 1.80 | 17 | 16 | 40 | |||
| 1.80 | 2.24 | 15 | 14 | 60 | |||
| 2.24 | 2.80 | 13 | 12 | 100 | |||
| 2.80 | 3.55 | 11 | 10 | 160 | |||
| 3.55 | 4.50 | 9 | 7 | 250 | |||
| 4.50 | 5.00 | - | 6 | 400 | |||
| Note: In view of continuous improvements in design & process specifications given above are subject to change without notice. | |||||||